CS Instruments VietNam, A2B2C2D1E1F1G1H3I1J2K2L1, DN200, A2B2C2D1E1F1G1H3I1J2K2L1, A2B2C1D1E1F1G1H3I1J2K2L1, VA 550, Phân phối chính hãng CS Instruments Vietnam
VA 550 Immersion sensor
ODER CODE: A2B2C2D1E1F1G1H3I1J2K2L1
- Pipe diameter : DN200
- Display: with Display
- Screw-in thread: 1/2“ NPT outer thread
- Mounting length / shaft length: 300 mm
- Option signal outputs / bus connection: 2 x 4...20 mA analogue output galv. isolated, pulse output RS 485 (Modbus-RTU)
- Accuracy class: ± 1% of measured value (precision)
- Medium: air
Accessories
- Connection cable for sensors 10 m with open ends: 0553 0109
A Screw neck: 3300 0006Flow sensor for heavy duty industrial applications
The immersion sensor VA 550 is the ideal flow sensor for installation into existing compressed air resp. gas lines from 3/4“ up to DN 500.
Special mechanical features:
- Robust impact-proof aluminum die cast housing for the outdoor area IP 67
- All medium-touching parts made from stainless steel 1,4571
- As immersion sensor suitable for 3/4“ up to DN 500
- On request with ATEX approval ATEX II 2G Ex d IIC T4
- On request with DVGW approval for natural gas (up to 16 bar)
- Pressure range up to 50 bar, special version up to 100 bar
- Temperature range up to 180 °C
- No moving parts, no wearout
- Sensor tip very robust, easy to clean
- Easy mounting and dismounting under pressure via 1/2“ ball valve
- Housing twistable, display twistable by 180°
- Safety ring for mounting and dismounting under pressure
- Depth scale for precise installation
Special measurement technology features:
- 4 values in the display: Nm³/h, Nm³, Nm/s, °C units freely adjustable
- Min/max values and daily/hours/minutes average values freely adjustable
- All measured values, settings like gas type, inner diameter, serial number and so on retrievable via Modbus RTU
- Comprehensive diagnosis functions readable at the display or remote access via Modbus like e. g. exceeding of max/min values °C, calibration cycle, error codes, serial number, all parameters readable and adjustable
- Notification in case of exceeding of the calibration cycle
- Standard version accuracy 1.5 % of m.v. ± 0.3 % of f.s.
- Precision version accuracy 1.0 % of m.v. ± 0.3 % of f.s. up to
- 40 calibration points with certificate
- Measuring span of 1 : 1000 (0.1 up to 224 m/s)
- Configuration and diagnosis via display, hand-held instrument
- PI 500, PC service software on-site
- Gas type (air, nitrogen, oxygen, argon and so on) freely adjustable
- Reference conditions °C and mbar/hPa freely adjustable
- Zero-point adjustment, leak flow volume suppression
- Pressure loss negligible
- Flow measurement in both directions via flow direction switch