125 psig inlet pressure | 105 °F inlet temp | ||||||
95 | 96 | 97 | 98 | 99 | 99.5 | |
Air-to-N2 Ratio - Ranges from 2.19:1 to 5.03:1 | ||||||
HMN-7 | 139.0 | 118.0 | 97.6 | 77.9 | 56.7 | 43.6 |
HMN-12 | 411.8 | 344.8 | 281.3 | 219.5 | 152.3 | 111.5 |
HMN-30 | 1025 | 858 | 701 | 546 | 381 | 279 |
HMN-60 | 2050 | 1716 | 1402 | 1092 | 762 | 558 |
HMN-90 | 3075 | 2574 | 2103 | 1638 | 1143 | 837 |
HMN-120 | 4100 | 3432 | 2804 | 2184 | 1524 | 1116 |
HMN-150 | 5125 | 4290 | 3505 | 2730 | 1905 | 1395 |
HMN-180 | 6150 | 5148 | 4206 | 3276 | 2286 | 1674 |
HMN-210 | 7175 | 6006 | 4907 | 3822 | 2667 | 1953 |
HMN-240 | 8200 | 6864 | 5608 | 4368 | 3048 | 2232 |
HMN-270 | 9225 | 7722 | 6309 | 4914 | 3429 | 2511 |
HMN-300 | 10250 | 8580 | 7010 | 5460 | 3810 | 2790 |
95 | 96 | 97 | 98 | 99 | 99.5 | |
Air-to-N2 Ratio - Ranges from 2.19:1 to 5.03:1 | ||||||
HMN-7HE | 55.6 | 47.3 | 39.5 | 31.9 | 23.7 | 18.6 |
HMN-12HE | 233 | 198 | 164 | 131 | 95 | 73 |
HMN-30HE | 507 | 429 | 356 | 284 | 207 | 159 |
HMN-60HE | 1014 | 858 | 712 | 568 | 414 | 318 |
HMN-90HE | 1521 | 1287 | 1068 | 852 | 621 | 477 |
HMN-120HE | 2028 | 1716 | 1424 | 1136 | 828 | 636 |
HMN-150HE | 2535 | 2145 | 1780 | 1420 | 1035 | 795 |
HMN-180HE | 3042 | 2574 | 2136 | 1704 | 1242 | 954 |
HMN-210HE | 3549 | 3003 | 2492 | 1988 | 1449 | 1113 |
HMN-240HE | 4056 | 3432 | 2848 | 2272 | 1656 | 1272 |
HMN-270HE | 4563 | 3861 | 3204 | 2556 | 1863 | 1431 |
HMN-300HE | 5070.0 | 4290.0 | 3560.0 | 2840.0 | 2070.0 | 1590.0 |