| Electrical data |
| Operating voltage [V] |
10...36 DC |
| Current consumption [mA] |
10; (24 V) |
| Protection class |
II |
| Reverse polarity protection |
yes |
| Outputs |
| Electrical design |
PNP |
| Output function |
normally open |
| Max. voltage drop switching output DC [V] |
2.5 |
| Permanent current rating of switching output DC [mA] |
100 |
| Switching frequency DC [Hz] |
800 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Detection zone |
| Sensing range [mm] |
4 |
| Operating distance [mm] |
0...3.25 |
| Increased sensing range |
yes |
| Accuracy / deviations |
| Correction factor |
steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
| Hysteresis [% of Sr] |
1...20 |
| Operating conditions |
| Ambient temperature [°C] |
0...100 |
| Protection |
IP 68; IP 69K; ("COP") |
| Tests / approvals |
| EMC |
|
| MTTF [years] |
1669 |
| UL approval |
|
| Mechanical data |
| Weight [g] |
355.5 |
| Housing |
threaded type |
| Mounting |
flush mountable |
| Dimensions [mm] |
M12 x 1 / L = 50 |
| Thread designation |
M12 x 1 |
| Materials |
stainless steel (1.4404 / 316L); sensing face: PEEK |
| Displays / operating elements |
| Display |
|
| Accessories |
| Accessories (supplied) |
|
| Remarks |
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Cable: 10 m, PVC, Ø 4.9 mm; 3 x 0.34 mm² |