OF05ZAT-AR, OF05ZAT-AR Aichi Tokei Denki Vietnam, Cảm biến lưu lượng OF05ZAT-AR, phân phối chính hãng Aichi Tokei Denki Vietnam
OF-ZMicroflow Sensor
Features
OF-Z flow sensor is suitable for measuring oil (heavy oil, light oil, heating oil, etc.).
It is a flow sensor with elliptic gears that measures microflow with accuracy.
It is a flow sensor with elliptic gears that measures microflow with accuracy.
・Measures heavy, light, heating oil, etc.
・Measures the microflow range with superior manufacturing technology.
・Good at measuring pulsating flow.
・Amplifier built-in magnetic sensor, which is strong against noise, is output in proportion to the flow velocity.
・Pulse output by open collectors or voltage pulse.
・Measures a wide range of flow rate with high accuracy.
・Simple structure due to the elliptic gears employed as a measuring principle.
・Capable of measuring various liquids.
・RoHS complaint (Complies with the RoHS directive to address the environmental issues.)
・Measures the microflow range with superior manufacturing technology.
・Good at measuring pulsating flow.
・Amplifier built-in magnetic sensor, which is strong against noise, is output in proportion to the flow velocity.
・Pulse output by open collectors or voltage pulse.
・Measures a wide range of flow rate with high accuracy.
・Simple structure due to the elliptic gears employed as a measuring principle.
・Capable of measuring various liquids.
・RoHS complaint (Complies with the RoHS directive to address the environmental issues.)
Specifications
Standard specifications
Model | OF05ZAT | OF10ZAT | OF05ZZT | OF10ZZT | |
---|---|---|---|---|---|
Flow rate range | Liquid viscosity0.3 – 0.8mPa・s | 0.085 – 0.85L/min | 0.7 – 5L/min | 0.085 – 0.85L/min | 0.7 – 5L/min |
Liquid viscosity0.8 – 2.0mPa・s | 0.05 – 0.85L/min | 0.35 – 5L/min | 0.05 – 0.85L/min | 0.35 – 5L/min | |
Liquid viscosity2.0 – 5.0mPa・s | 0.017 – 0.85L/min | 0.17 – 5L/min | 0.017 – 0.85L/min | 0.17 – 5L/min | |
Liquid viscosity5.0 – 200mPa・s | 0.085 – 0.85L/min | 0.085 – 5L/min | 0.085 – 0.85L/min | 0.085 – 5L/min | |
Accuracy | ±2%RS(In the standard installation position) | ||||
Measurable liquid | Types of measurable liquid | Please decide based on the major materials exposed to the fluid, which are described below. | |||
Major measurable liquid | Cold and hot water and heating, light and heavy oil | Mildly acidic and mildly alkaline liquid | |||
Maximum operating pressure | 0.5MPa(When the liquid is at 20°C). | ||||
Pressure loss | 4 kPa or less | 10 kPa or less | 4 kPa or less | 10 kPa or less | |
Fluid temperature range | -10 to +70℃(No condensing) | ||||
Responsiveness | -10 to +70℃ 35~85%RH(No condensing) | ||||
Output signal | Voltage pulse output | Voltage pulse 3-wireLength of wire: Approx. 480 mmVoltage pulse duty ratio 2/8 < A/B < 8/2When voltage is applied at 12 VDC or less,High: 10 VDC or moreLow: 1 VDC or less | |||
Open collector output | Open collector pulse (Capacity: 6 mA DC or less)Length of 4 lead wire: Approx. 600 mm | ||||
Pulse constant | 0.46mL/P | 2.5mL/P | 0.46mL/P | 2.5mL/P | |
Maximum frequency | Approx. 30Hz | Approx. 33Hz | Approx. 30Hz | Approx. 33Hz | |
Minimum pulse width | Approx. 0.0065s | Approx. 0.006s | Approx. 0.0065s | Approx. 0.006s | |
Applied voltage range | 3 – 24VDC *1 | ||||
Power consumption | 0.2VA or less | ||||
Structure | Splash-proof structure (IP64 compatible) for indoor use | ||||
Connection | R1 / 4 | R1 / 2 | R1 / 4 | R1 / 2 | |
Mass | Approx. 100 g | Approx. 140 g | Approx. 100 g | Approx. 140 g | |
Major materials of the part exposed to liquid | Case | PPS | |||
Rotor | PPS | ||||
O-ring | NBR | FKM | |||
Shaft | SUS304 | SiC |
– If the fluid might contain fine particles, please install the filter with a #80 mesh screen or higher before the flow sensor.
– Do not measure gasoline, sodium hydroxide (caustic soda), oxygenated water (Oxydol) and acidum hydrochloricum (strong acid fluid).
*1. Apply the same voltage to the sensor power supply (red – black) and pulse output (blue and white – black).
(Applicable only for open collector output)
Dimensions
(Unit:mm)
Model | OF05 | OF10 |
---|---|---|
A | 80 | 90 |
B | 46.9 | 46.9 |
C | 46.9 | 46.9 |
D | 8 | 8.5 |
E | 27.3 | 40.3 |
Other information
Wiring method [Voltage pulse output]
Wiring method [Open collector output]
The pull-up resistance R on the side of the open collector output shall be 50 KΩ or less. However, make sure the output sink current (Is) is within 6 mA.
* Apply the same voltage to the sensor power supply (red – black) and pulse output (blue and white – black). (Applicable only to open collector output)
Standard installation position
Description of symbols
Denatured PPO | Polyphenylene oxide |
PP | Polypropylene |
PPS | Polyphenylene Sulfide |
ETFE | Ethylene-tetrafiuoro ethylene |
POM | Polyacetal or Polyoxymethylene |
PA | Polyamide |
SUS304 | Stainless |
SCS13 | Stainless steel castings |
FKM | Fluoro Rubber |
SiC | Silicon Carbide Ceramics |
Sm-Co | Samarium-Cobalt |
EPDM | Ethylene propylene Rubber |
Ba-Fe | Barium-Ferrite |
PVC | Polyvinyl Choride |
O.C. | Open Collector |
NBR | Acrylonitrile-Butadiene Rubber |
Caution for the imitation (copy product) of micro stream sensor OF-ZAT. |
Recently, inferior imitations of OF-ZAT (copy products) has been appeared around the world. In addition, the trouble caused by using the imitation (copy product) has often been reported to us. Even if you purchased the imitation (copy product) without knowing the product cannot only be warranted but also such as the repair of failure cannot be supported at all. Also we shall not owe the responsibility of damage caused by the low quality of imitation (copy product).At the time of purchasing regular article OF-ZAT, please drop your inquiry to the “Contact Us” on our web site. |
・Specifications are subject to change without notice.
・Product Warranties
・Product Warranties