Apiste Precision Air PAU-AZ3000SE
Xuất sứ: Apiste
Nhà cung cấp: PITESCO Viet Nam
Hãng sản xuất: Apiste
Specifications
Cooling Method | Air-Cooled Type |
---|---|
Type | Temperature Controller (energy conservation) |
Cooling Capacity (W) | 2600/2950 |
Heating Capacity (W) | 3250/3550 |
Temperature Control Precision (°C) | +-0.1 |
Setting Temperature Range (°C) | 11~42 |
Use Area Temperature (°C) | 15~35 (change in temperature gradient: within 1°C/1h) |
Use Area Humidity (%RH) | 15~85(change in temperature gradient: within 5%/1h) (No condensation) |
Processed Air Volume (m2/min)(50Hz) | 9.5/10 |
External Dimensions(mm) | H1115×W450×D700 |
Volume (kg) | 88 |
Coating Color | Ivory(JPMA: Semi-gloss Y22-85B) |
Blower Duct Connection Diameter (mm) | φ150 with damper |
Rated Voltage (V) | Three-phase AC200 |
Consumption Current (A) | 4.45/4.3 |
Wattage (W) | 965/1245 |
Drain Discharge Water Connection Diameter (mm) | 20A Female socket (Rp3/4) |
Coolant | HFC-134a 730g |
Exhaust Air Volume (m3/min) | 20/24 |
Safety Circuit/Main Circuit | Earth leakage circuit breaker (10A 30mA) |
Safety Circuit/Blower | Overcurrent relay, delay timer (3 minutes), surge absorber |
Safety Circuit/Compressor | Anti-freezing mechanism cooler prevention, overcurrent relay, motor protectors, surge absorber |
Output/Main Unit Malfunction Output | No-voltage contact a (AC250V / 2A / Resistive load) |
Output/Temperature Control Top-Bottom Limit Alarm | No-voltage contact a (AC250V / 2A / Resistive load) |
*Cooling and heating capacity is the value in the body of the balloon when RH 25°C / 40% ambient temperature. *The temperature control precision constant temperature and humidity chamber JTMK01 - are based on the method set forth in Section 2 (Japan Testing Machinery Association) how to display performance test methods and performance. *Guarantee the accuracy of the point and one outlet in reading body temperature controller equipped with air conditioners, duct thermal interference due accuracy is not covered under warranty. *In addition, this product is intended to suppress the fluctuation of air temperature, but do not guarantee the absolute value of the temperature. (For bias correction function is equipped.) *Ambient temperature and humidity. Some may not be able to also control the temperature within the range set. *Is the value of the processing air volume in the outlet body. *Dimensions above are body dimensions. Mounting flange, protrusions are not included. *Current consumption, power consumption may vary depending on surrounding environment temperature and humidity and conditions of use. *For air-cooled type, there is waste heat from the equipment. (With exhaust chamber as an option) *Ambient environment at low temperatures below ambient temperature of the protective device is used to work, we will automatically shut down the compressor only. *In that case, we can not guarantee the accuracy of the above, please use the ambient temperature in the range of use. *The actual mounting on the check, I hope specification contained in the instruction manual, the precautions. *If you need instruction manual in advance on the design, please contact your nearest sales office. |
Parts list supplied
Anchor Mount | 2 |
---|---|
INSULOK Tie | 2 |
User Manual | 1 |
Optional Parts List
Duct Set | o |
---|---|
Return Chamber | o |
Exhaust Chamber | o |
Delivery, please contact us. |
Dimensions
Sensor dimensions
Temperature Control Range Chart
Range showed a correlation between temperature and ambient temperature the unit can be configured.
Temperature control accuracy of this unit (+- 0.5 °C) is applied to the set temperature within this range.
[Range: temperature control *2]
Although outside the scope of warranty (+- 0.5 °C) temperature control accuracy, range and showed a correlation of temperature and ambient temperature the unit can be configured.
*Measurement conditions
AC100V 60Hz (1) single-phase power supply:
Ambient humidity: 40% RH (2)
Blowing air volume: 1.0m 3 / min (3)
Sensor is mounted in the body of the performance of the outlet air outlet body (4)
The body, without mounting the fan duct (5)