Main Features Features Values
Protection Protection Level (standard) IP56
Temperature Working Temperature (°C) -10... +50
Power Supply Power Supply Range (standard) 24Vac/115Vac/230Vac 50-60Hz
Power Consumption 100W
Display Display Type 7-segment display
Resolution 3 digits
Display Color (standard) Red
Inputs Digital Inputs (nr) 3-4 opto-isolated inputs
Pressure Input ok
Pressure Range -99/+999dPa, -99/+999mmH2O, -9.9/+99.9mBar, -0.99/+9.99kPa, -7.5/+75.0mmHg
Outputs Relay Outputs (nr) 1-2
Relay Output Power 2A/115Vac
Coils Control Voltage 24Vac, 115Vac, 230Vac or 24Vdc
4-20mA Output optional
Functions Cyclic Management ok
Delta Pressure Management ok
Customizing Cycles ok
Remote Start/Stop ok
Autopause ok
Precoating ok
Post-cleaning ok
Cleaning cycle ok (standard)
Coils can be activated simultaneously for each output (nr) 2
Broken Coil Control ok
Broken Valve Control ok
Pressure Tank Control ok
Broken Bag Control with D.Probe ok
Serial Ports RS485 optional
System Maximum Driver Managed 4... 96 electrovalves
Type MASTER
Type of driver connectable electrovalve/SPV
Type of control driver triac outputs
Controls Buttons (nr) 3
Application Type Complex Small, Medium and Big size dust collectors

ECOMATIC S

Classic Method, state-of-the-art performances: basic functions to manage the cleaning cycle, with hour counter and cycles counter.

ECOMATIC S
 
Main Features Features Values
Protection Protection Level (standard) IP56
Temperature Working Temperature (°C) -10... +50
Power Supply Power Supply Range (standard) 24Vac/115Vac/230Vac 50-60Hz
Power Supply Range (optional) 22... 34Vdc
Power Consumption 50W
Display Display Type 7-segment display
Resolution 3 digits
Display Color (standard) Red
Inputs Digital Inputs (nr) 1 opto-isolated inputs
Pressure Input ok
Pressure Range -99/+999dPa, -99/+999mmH2O, -9.9/+99.9mBar, -0.99/+9.99kPa, -7.5/+75.0mmHg
Outputs Relay Outputs (nr) 1
Relay Output Power 2A/115Vac
Coils Control Voltage 24Vac, 115Vac, 230Vac or 24Vdc
4-20mA Output optional
Functions Cyclic Management ok
Delta Pressure Management ok
Precoating ok
Post-cleaning ok
Cleaning cycle ok (standard)
Coils can be activated simultaneously for each output (nr) 2
System Maximum Driver Managed 4... 96 electrovalves
Type MASTER
Type of driver connectable electrovalve/SPV
Type of control driver triac outputs
Controls Buttons (nr) 3
Application Type Regular Small, Medium and Big size dust collectors