CLASSIC SOLUTION
ECOMATIC - ECONOMIZER
ECOMATIC NET
Classic Method, state-of-the-art performances: advanced functions to manage the cleaning cycle, large number of parameters and management via serial line.

| Main Features | Features | Values |
|---|---|---|
| Protection | Protection Level (standard) | IP56 |
| Temperature | Working Temperature (°C) | -10... +50 |
| Power Supply | Power Supply Range (standard) | 24Vac/115Vac/230Vac 50-60Hz |
| Power Consumption | 100W | |
| Display | Display Type | 7-segment display |
| Resolution | 3 digits | |
| Display Color (standard) | Red | |
| Inputs | Digital Inputs (nr) | 3-4 opto-isolated inputs |
| Pressure Input | ok | |
| Pressure Range | -99/+999dPa, -99/+999mmH2O, -9.9/+99.9mBar, -0.99/+9.99kPa, -7.5/+75.0mmHg | |
| Outputs | Relay Outputs (nr) | 1-2 |
| Relay Output Power | 2A/115Vac | |
| Coils Control Voltage | 24Vac, 115Vac, 230Vac or 24Vdc | |
| 4-20mA Output | optional | |
| Functions | Cyclic Management | ok |
| Delta Pressure Management | ok | |
| Customizing Cycles | ok | |
| Remote Start/Stop | ok | |
| Autopause | ok | |
| Precoating | ok | |
| Post-cleaning | ok | |
| Cleaning cycle | ok (standard) | |
| Coils can be activated simultaneously for each output (nr) | 2 | |
| Broken Coil Control | ok | |
| Broken Valve Control | ok | |
| Pressure Tank Control | ok | |
| Broken Bag Control with D.Probe | ok | |
| Serial Ports | RS485 | optional |
| System | Maximum Driver Managed | 4... 96 electrovalves |
| Type | MASTER | |
| Type of driver connectable | electrovalve/SPV | |
| Type of control driver | triac outputs | |
| Controls | Buttons (nr) | 3 |
| Application | Type | Complex Small, Medium and Big size dust collectors |
ECOMATIC S
Classic Method, state-of-the-art performances: basic functions to manage the cleaning cycle, with hour counter and cycles counter.

| Main Features | Features | Values |
|---|---|---|
| Protection | Protection Level (standard) | IP56 |
| Temperature | Working Temperature (°C) | -10... +50 |
| Power Supply | Power Supply Range (standard) | 24Vac/115Vac/230Vac 50-60Hz |
| Power Supply Range (optional) | 22... 34Vdc | |
| Power Consumption | 50W | |
| Display | Display Type | 7-segment display |
| Resolution | 3 digits | |
| Display Color (standard) | Red | |
| Inputs | Digital Inputs (nr) | 1 opto-isolated inputs |
| Pressure Input | ok | |
| Pressure Range | -99/+999dPa, -99/+999mmH2O, -9.9/+99.9mBar, -0.99/+9.99kPa, -7.5/+75.0mmHg | |
| Outputs | Relay Outputs (nr) | 1 |
| Relay Output Power | 2A/115Vac | |
| Coils Control Voltage | 24Vac, 115Vac, 230Vac or 24Vdc | |
| 4-20mA Output | optional | |
| Functions | Cyclic Management | ok |
| Delta Pressure Management | ok | |
| Precoating | ok | |
| Post-cleaning | ok | |
| Cleaning cycle | ok (standard) | |
| Coils can be activated simultaneously for each output (nr) | 2 | |
| System | Maximum Driver Managed | 4... 96 electrovalves |
| Type | MASTER | |
| Type of driver connectable | electrovalve/SPV | |
| Type of control driver | triac outputs | |
| Controls | Buttons (nr) | 3 |
| Application | Type | Regular Small, Medium and Big size dust collectors |