CS2G-CAP_Proton Vietnam, Thiết bị đo đường kính cáp, Proton PTC Vietnam
Xuất sứ: UK
Hãng sản xuất: Proton
EXTRUSION CONTROL
NEXiS® CS2G-CAP Series Extrusion Controller
Control of insulation extruder to maintain a target insulation capacitance.
- Integrates with Proton Products CG Series Capacitance Gauges for insulation capacitance measurement.
- 2-row, 5-digit, 7-segment LED display.
- Panel mounted; optional stand-alone enclosure is available
NEXiS® CS2G-CAP - connector panel view
Introduction
The Proton Products NEXiS® CS2G-CAP controller is for use on wire insulation extrusion lines.
NEXiS® CS2G-CAP controllers connect to Proton Products InteliSENS®Capacitance Gauges and Speed and Length Gauges for measurement of insulation capacitance and line speed respectively. These measurements are then fed into a PI feedback controller whose fully-isolated and floating output may be used to drive insulation extruders or capstan drives.
Insulation capacitance is thus actively controlled and kept in tolerance by the NEXiS® CS2G-CAP controller.
NEXIS® CS2G-CAP PRODUCTION LINE CONFIGURATION
Specifications
Screen | 2 row, 7 segment, 5 digit display - Upper row 0.8” (20.32mm) high; lower row 0.5” (12.7mm) high | |||||
Display resolution | 0.1pF/m | |||||
Presets | Required capacitance | Upper tolerance | Lower tolerance | Capacitance error | Control output % | |
Serial communications | RS232 | USB | CANbus - (for connection to 1× CG Series gauge) | |||
Line speed inputs | Analogue | Two inputs available for 0 to 10V and 0 to 50V analogue line speed signals; end-user configurable scaling | ||||
Pulse | Two inputs available for 0 to 3V and 0 to 10V pulsed line speed signals; maximum frequency 250 kHz; end-user configurable scaling | |||||
3×Relay contact outputs | Function | Capacitance gauge OK | Upper tolerance exceeded | Lower tolerance exceeded | ||
Electrical | Maximum voltage | 50VDC / 30VAC | ||||
Maximum current | 500mA | |||||
On resistance (@ 100mA) | < 0.1Ω | |||||
Off resistance | > 10 MΩ | |||||
Analogue output 1 | Function | Measured capacitance | ||||
Electrical | Output voltage range | 0V to +10V | ||||
Maximum output current | 2mA | |||||
Resolution | 16-bit | |||||
Output voltage scaling is end-user configurable | ||||||
Analogue output 2 | Function | Capacitance deviation | ||||
Electrical | Output voltage range | -10V to +10V | ||||
Maximum output current | 2mA | |||||
Resolution | 16-bit | |||||
Output voltage scaling is end-user configurable | ||||||
Control algorithm | Advanced Control Algorithm (ACA) |
Specification
|
Minimum
|
Typical
|
Maximum
|
Units
|
---|---|---|---|---|
Weight | 2.5 | kg | ||
5.5 | lb | |||
Length | 230 | mm | ||
9.1 | inch | |||
Width | 213.1 | mm | ||
8.4 | inch | |||
Height | 128.5 | mm | ||
5.1 | inch | |||
Power supply voltage (rms) | 84 | 264 | VAC | |
Power supply frequency | 47 | 440 | Hz | |
Power supply current (rms) | 1 | A | ||
Power consumption | 35 | W | ||
Ambient temperature | 5 | 45 | °C | |
41 | 113 | °F | ||
Relative humidity @ 38°C / 105°F | 90 | % | ||
Ingress Protection (IP) rating | IP50 | - | ||
PI Controller output voltage | -10 | 10 | V | |
PI Controller output current | 10 | mA | ||
PI Controller output resistance | 10 | Ω | ||
PI Controller resolution | 12 | bit |