Primary GLO 5TR
Input voltage nominal VDC 5
Input current typical mA 15
maximum mA 17
Input voltage range minimum VDC 3
maximum VDC 7
Input impedance typical 0,3
Switch-on voltage typical VDC 2,7
maximum VDC 3
Switch-off voltage typical VDC 2,5
minimum VDC 2
     
Secondary GLO 5TR
Load voltage minimum VAC 0
nominal VAC 240
maximum VAC 265
Load current maximum A 2,5
Load current 20 ms maximum A 90
Voltage drop at maximum load typical VAC 1
Switch-on delay typical ms 0,5
maximum ms 1
Switch-off delay typical ms -
maximum ms 11
Load inductance at 240 VAC 2,5 A range cos Φ 0...1
Leakage current (off-state) typical mA 1,5
dv/dt, off-state typical V/µs 200

AC-output relay for resistive and inductive loads. 