Nitrogen Gas Generator Mini-CUBE SERIES(0.5NL/min-8NL/min)
Xuất sứ: Japan
Nhà cung cấp: Pites
Hãng sản xuất: KOFLOC
Nitrogen Gas Generator Mini-CUBE SERIES(0.5NL/min-8NL/min)
The Mini-CUBEseries,which was developed for small volume use,offers 99 to 99.999% purity and its ultra-small body can be placed on a desktop.A DC inverter compressor has also been used,allowing energy-saving functions as a tandard feature. This series also features a new design in harmony with peripheral equipment,making it optimal incidental equipment for analysis and culture devices,as well as soldering devices.
| TYPE | Nitrogen Gas Generator Mini-CUBE Series | |||||||
| M1NTS-0.3-95 | M1NTS-0.3-96 | M1NTS-0.3-97 | M1NTS-0.3-98 | M2NTS-0.3 | M3NTS-0.3 | M4NTS-0.3 | M5NTS-0.3 | |
| Purity ※1 | 95% | 96% | 97% | 98% | 99% | 99.9% | 99.99% | 99.999% ※5 |
| Generating volume ※2 | 8.0NL/min | 7.0NL/min | 6.0NL/min | 5.0NL/min | 4.0NL/min | 2.4NL/min | 1.2NL/min | 0.5NL/min |
| Pressure | 0.3MPa | 0.4MPa | 0.5MPa | |||||
| Dew point | Below'-55℃ | |||||||
| Surrounding temperature | 5~35℃ ※6 | |||||||
| Surrounding humidity | 10~80%RH | |||||||
| Device dimensions | 310mm(W)×392mm(D)×310mm(H) | |||||||
| Device weight | Approx. 25kg | |||||||
| Sound level ※3 | 55dB(A) | |||||||
| Electricity consumption ※4 | 0.3kW | |||||||
| Power supply voltage | AC100~240V 1φ 50/60Hz | |||||||
| ※1 N2+Ar levels | ||||||||
| ※2 Values obtained under environment conditions of 20℃ surrounding temperature and 60% relative humidity(RH) are converted for atmospheric pressure of 0℃. | ||||||||
| The amount of N2 gas that can be produced may decrease due to surrounding temperature and humidity. | ||||||||
| ※3 Actual measurement values at 1m in front of the device,at 1m above the ground,in a semi-anechoice chamber. | ||||||||
| ※4 Energy consumption is the total nominal output of compressor,fan and PSA control part. | ||||||||
| ※5 Internal densitometer indicated values were used as a guide for the 99.999% specification. When precision is required, a high performance densitometer can be | ||||||||
| fitted as an option. | ||||||||
| ※6 When intake temperature is high, equipment performance decreases. There is also a danger that this could lead to accelerated maintenance cycle. | ||||||||
| Ventilate the room when surronunding temperature is high. | ||||||||
| For overseas specifications or special specifications not in our catalogue, please contact relevant staff at our company. | ||||||||
| Product improvements may lead to specifications changing without notice. | ||||||||
| This equipment does not conform to CE and RoHs directive at the moment. | ||||||||




Mr. Hà
live:ha_1652