The Mini-CUBEseries,which was developed for small volume use,offers 99 to 99.999% purity and its ultra-small body can be placed on a desktop.A DC inverter compressor has also been used,allowing energy-saving functions as a tandard feature. This series also features a new design in harmony with peripheral equipment,making it optimal incidental equipment for analysis and culture devices,as well as soldering devices.
TYPE | Nitrogen Gas Generator Mini-CUBE Series | |||||||
M1NTS-0.3-95 | M1NTS-0.3-96 | M1NTS-0.3-97 | M1NTS-0.3-98 | M2NTS-0.3 | M3NTS-0.3 | M4NTS-0.3 | M5NTS-0.3 | |
Purity ※1 | 95% | 96% | 97% | 98% | 99% | 99.9% | 99.99% | 99.999% ※5 |
Generating volume ※2 | 8.0NL/min | 7.0NL/min | 6.0NL/min | 5.0NL/min | 4.0NL/min | 2.4NL/min | 1.2NL/min | 0.5NL/min |
Pressure | 0.3MPa | 0.4MPa | 0.5MPa | |||||
Dew point | Below'-55℃ | |||||||
Surrounding temperature | 5~35℃ ※6 | |||||||
Surrounding humidity | 10~80%RH | |||||||
Device dimensions | 310mm(W)×392mm(D)×310mm(H) | |||||||
Device weight | Approx. 25kg | |||||||
Sound level ※3 | 55dB(A) | |||||||
Electricity consumption ※4 | 0.3kW | |||||||
Power supply voltage | AC100~240V 1φ 50/60Hz | |||||||
※1 N2+Ar levels | ||||||||
※2 Values obtained under environment conditions of 20℃ surrounding temperature and 60% relative humidity(RH) are converted for atmospheric pressure of 0℃. | ||||||||
The amount of N2 gas that can be produced may decrease due to surrounding temperature and humidity. | ||||||||
※3 Actual measurement values at 1m in front of the device,at 1m above the ground,in a semi-anechoice chamber. | ||||||||
※4 Energy consumption is the total nominal output of compressor,fan and PSA control part. | ||||||||
※5 Internal densitometer indicated values were used as a guide for the 99.999% specification. When precision is required, a high performance densitometer can be | ||||||||
fitted as an option. | ||||||||
※6 When intake temperature is high, equipment performance decreases. There is also a danger that this could lead to accelerated maintenance cycle. | ||||||||
Ventilate the room when surronunding temperature is high. | ||||||||
For overseas specifications or special specifications not in our catalogue, please contact relevant staff at our company. | ||||||||
Product improvements may lead to specifications changing without notice. | ||||||||
This equipment does not conform to CE and RoHs directive at the moment. |