Apiste Panel Cooling Units Standard ENC-AR422L-CU, AR620L-CU, AR1120L-CU, AR1652L-CU, AR2200L-CU, AR2900L-CU, G310EX, G320EX, G510EX, G710EX, G1110EX
Xuất sứ: Apiste
Nhà cung cấp: PITESCO Viet Nam
Hãng sản xuất: Apiste
ENC-AR422L-CU

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 400/450 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 45 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H450×W300×D115 |
| Volume (kg) | 13 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC200/Single-phase AC200 to 220 |
| Consumption Current/Rating (A) | 1.8/1.7 |
| Consumption Current/MAX (A) | 1.9/1.8 |
| Starting Current (A) | 4.0/4.2 |
| Consumption Voltage/Rating (W) | 295/330 |
| Consumption Voltage/MAX (W) | 335/365 |
| Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 EN61000-6-2 EN61000-6-4 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 80g |
| Noise (dB) | 59/61.5 |
| External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
| Display | LED / RUN LED display / temperature error in the panel |
| Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
ENC-AR620L-CU

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 500/600 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H450×W350×D200 |
| Volume (kg) | 16 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 1.8/1.6 |
| Consumption Current/MAX (A) | 2.1/1.9 |
| Starting Current (A) | 4.0/4.2 |
| Consumption Voltage/Rating (W) | 280/270 |
| Consumption Voltage/MAX (W) | 370/360 |
| Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
| Vibration Resistance | JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 100g |
| Noise (dB) | 63/67 |
| External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
| Display | LED / RUN LED display / temperature error in the panel |
| Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
ENC-AR1120L-CU

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 950/1100 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H730×W300×D230 |
| Volume (kg) | 23 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 2.6/2.4 |
| Consumption Current/MAX (A) | 3.1/3.2 |
| Starting Current (A) | 7.5/7.1 |
| Consumption Voltage/Rating (W) | 440/460 |
| Consumption Voltage/MAX (W) | 560/570 |
| Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a |
| Noise (dB) | 64/68 |
| External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
| Display | LED / RUN LED display / temperature error in the panel |
| Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
ENC-AR1652L-CU

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 1450/1600 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 55 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H1000×W400×D230 |
| Volume (kg) | 39 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 3.8/3.6 |
| Consumption Current/MAX (A) | 4.7/4.6 |
| Starting Current (A) | 16.5/15.5 |
| Consumption Voltage/Rating (W) | 640/710 |
| Consumption Voltage/MAX (W) | 830/900 |
| Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 430g |
| Noise (dB) | 68/72 |
| External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
| Display | LED / RUN LED display / temperature error in the panel |
| Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
ENC-AR2200L-CU

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 2000/2200 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 55 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H1200×W450×D230 |
| Volume (kg) | 48 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Three phase AC200 |
| Consumption Current/Rating (A) | 3.4/3.2 |
| Consumption Current/MAX (A) | 4.4/4.1 |
| Starting Current (A) | 27/25 |
| Consumption Voltage/Rating (W) | 815/950 |
| Consumption Voltage/MAX (W) | 1100/1200 |
| Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 570g |
| Noise (dB) | 68/72 |
| External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
ENC-AR2900L-CU

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 2600/2900 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 55 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H1380×W450×D230 |
| Volume (kg) | 57 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Three phase AC200 |
| Consumption Current/Rating (A) | 4.9/4.6 |
| Consumption Current/MAX (A) | 5.7/5.8 |
| Starting Current (A) | 31/30 |
| Consumption Voltage/Rating (W) | 1230/1430 |
| Consumption Voltage/MAX (W) | 1570/1780 |
| Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 580g |
| Noise (dB) | 70/73 |
| External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
| Display | LED / RUN LED display / temperature error in the panel |
| Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
ENC-G310EX

| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 280/300 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H230×W590×D200 |
| Volume (kg) | 16 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 3.4/3.2 |
| Consumption Current/MAX (A) | 4.0/4.2 |
| Starting Current (A) | 7.4/7.7 |
| Consumption Voltage/Rating (W) | 290/310 |
| Consumption Voltage/MAX (W) | 360/410 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 90g |
| Noise (dB) | 62/65 |
| External Output | Alarm output (a contact: No-voltage resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | EN60335-1 EN60335-2-40/EN61000-6-2 EN61000-6-4 |
| Environmental Response | RoHS |
ENC-G320EX

| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 280/300 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H230×W590×D200 |
| Volume (kg) | 16 Translate |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 1.8/1.5 |
| Consumption Current/MAX (A) | 1.9/1.7 |
| Starting Current (A) | 4.0/4.2 |
| Consumption Voltage/Rating (W) | 280/265 |
| Consumption Voltage/MAX (W) | 340/330 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 90g |
| Noise (dB) | 62/65 |
| External Output | Alarm output (a contact: No-voltage resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | EN60335-1 EN60335-2-40/EN61000-6-2 EN61000-6-4 |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 4 (M6 x L12) |
|---|---|
| Exhaust Hose | 3m |
| L-pipe | 2 |
| INSULOK Tie | 6 |
| Mounting nut | 4(M6) |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for G320EX |
|---|---|
| External Fan | Air fan for G320EX |
| Filter | ENC-F-28 |
| Electrical Board | Substrate for AR310EX/AR320EX |
ENC-G510EX

| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 450/500 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H230×W450×D250 |
| Volume (kg) | 15 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 3.3/3.0 |
| Consumption Current/MAX (A) | 3.6/3.9 |
| Starting Current (A) | 7.4/7.7 |
| Consumption Voltage/Rating (W) | 270/280 |
| Consumption Voltage/MAX (W) | 320/360 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 90g |
| Noise (dB) | 60/65 |
| External Output | Alarm output (a contact: No-voltage resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | EN60335-1 EN60335-2-40/EN61000-6-2 EN61000-6-4 |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 4 (M6 x L12) |
|---|---|
| Exhaust Hose | 3m |
| L-pipe | 2 |
| INSULOK Tie | 6 |
| Mounting nut | 4(M6) |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for G510EX |
|---|---|
| External Fan | Air fan for G510EX |
| Filter | ENC-F-28 * 2 |
| Electrical Board | Substrate for G510EX/G520EX |
ENC-G710EX

| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 600/700 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H332×W550×D270 |
| Volume (kg) | 22 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 3.2/3.3 |
| Consumption Current/MAX (A) | 3.9/4.1 |
| Starting Current (A) | 7.4/7.7 |
| Consumption Voltage/Rating (W) | 250/300 |
| Consumption Voltage/MAX (W) | 350/390 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 150g |
| Noise (dB) | 60/65 |
| External Output | Alarm output (a contact: No-voltage resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | EN60335-1 EN60335-2-40/EN61000-6-2 EN61000-6-4 |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 4 (M6 x L12) |
|---|---|
| Exhaust Hose | 3m |
| L-pipe | 2 |
| INSULOK Tie | 6 |
| Mounting nut | 4(M6) |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for G710EX |
|---|---|
| External Fan | Air fan for G710EX |
| Filter | ENC-F-21 * 2 |
| Electrical Board | Substrate for G710EX/G720EX |
ENC-G1110EX

| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 950/1100 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H318×W600×D353 |
| Volume (kg) | 27 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 5.4/4.8 |
| Consumption Current/MAX (A) | 6.3/6.6 |
| Starting Current (A) | 15.6/14.7 |
| Consumption Voltage/Rating (W) | 440/470 |
| Consumption Voltage/MAX (W) | 570/630 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 240g |
| Noise (dB) | 60/65 |
| External Output | Alarm output (a contact: No-voltage resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | EN60335-1 EN60335-2-40/EN61000-6-2 EN61000-6-4 |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 4 (M6 x L12) |
|---|---|
| Exhaust Hose | 3m |
| L-pipe | 2 |
| INSULOK Tie | 6 |
| Washer | 2(M6) |
| Wind Direction Louver | 1 |
| Mounting nut | M4 * 2 /M6 * 4 |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for G1110EX |
|---|---|
| External Fan | Air fan for G1110EX |
| Filter | ENC-F-21 * 2 |
| Electrical Board | Substrate for G1110EX/G1120EX |
ENC-AR520EX-CU

| Mount Type | Roof-mount |
|---|---|
| Cooling Capacity (W) | 450/500 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 20 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H230×W450×D250 |
| Volume (kg) | 15 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 1.9/1.4 |
| Consumption Current/MAX (A) | 2.0/1.8 |
| Starting Current (A) | 4.0/4.2 |
| Consumption Voltage/Rating (W) | 280/260 |
| Consumption Voltage/MAX (W) | 360/320 |
| Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 90g |
| Noise (dB) | 60/65 |
| External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
| Display | LED / RUN LED display / temperature error in the panel |
| Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |




Mr. Hà