ADVANCED SERIAL SYSTEM
Model: ECOSERIAL 3

| Main Features | Features | Values |
|---|---|---|
| Dimensions | External Dimensions ( L x H x W mm ) | 254x200x135 |
| Weight (kg) | 2,6 | |
| Protection | Protection Level (standard) | M IP55 / F IP56 |
| Temperature | Working Temperature (°C) | -20... +60 vers.CE (OPT -40°C), -40... +65 vers. UL |
| Power Supply | Power Supply Range (standard) | 90-270Vac 50-60Hz |
| Power Consumption | 10W | |
| Display | Display Type | LCD |
| Resolution | 128x64 | |
| Display Color (standard) | yellow-green | |
| Inputs | Digital Inputs (nr) | 4 opto-isolated inputs |
| Pressure Input | ok | |
| Pressure Range | 0/+9999mmH2O, 0/+9999Pa, 0/+9.999kPa, 0/+99.99mBar | |
| Analog Input | optional | |
| Outputs | Relay Outputs (nr) | 4 |
| Relay Output Power | 8A/270Vac | |
| 4-20mA Output | optional | |
| Functions | Cyclic Management | ok |
| Delta Pressure Management | ok | |
| Customizing Cycles | ok | |
| Remote Start/Stop | ok | |
| Autopause | ok | |
| Post-cleaning | ok | |
| Cleaning cycle | ok (custom) | |
| Coils can be activated simultaneously for each output (nr) | 128 | |
| Broken Coil Control | ok | |
| Broken Valve Control | ok | |
| Pressure Tank Control | ok | |
| Broken Bag Control with D.Probe | ok (advanced) | |
| SMS Remote Control | ok | |
| Serial Ports | RS485 | ok |
| System | Maximum Driver Managed | 64 RPA / 16 RPC |
| Type | MASTER | |
| Type of driver connectable | RPA/RPC | |
| Type of control driver | SERIAL | |
| Management cell | ok | |
| Controls | Buttons (nr) | 4 |
| Application | Type | Big Process dust collectors |
Model: RPA-612

| Main Features | Features | Values |
|---|---|---|
| Dimensions | External Dimensions ( L x H x W mm ) | 346x134x72 |
| Protection | Protection Level (standard) | IP66, TYPE 4X |
| Temperature | Working Temperature (°C) | -40... +65 |
| Power Supply | Power Supply Range (standard) | 90-270Vac |
| Power Consumption | 90Vac 9VA, 270Vac 18.9VA | |
| Inputs | Digital Inputs (nr) | 2 |
| Analog Input | ok | |
| Outputs | Relay Outputs (nr) | 2 |
| Relay Output Power | 2A 30Vdc/250Vac resistive | |
| Coils Control Voltage | 24Vdc | |
| Functions | Cyclic Management | ok |
| Broken Coil Control | ok | |
| Broken Valve Control | ok | |
| Pressure Tank Control | ok | |
| Serial Ports | RS485 | ok |
| System | Type | SLAVE |
| Maximum number of coil | 12 | |
| Type of control driver | RS485 |
Model: RPC

| Main Features | Features | Values |
|---|---|---|
| Dimensions | External Dimensions ( L x H x W mm ) | 346x134x72 |
| Protection | Protection Level (standard) | IP65 |
| Temperature | Working Temperature (°C) | -10... +60 standard version, -20... +60 with one heater, -40... +60 with two heater |
| Power Supply | Power Supply Range (standard) | 90-270Vac |
| Power Consumption | 90Vac 9VA, 270Vac 18.9VA | |
| Inputs | Digital Inputs (nr) | 8 opto-isolated inputs |
| Analog Input | ok | |
| Outputs | Relay Outputs (nr) | 4 |
| Relay Output Power | 2A 30Vdc/250Vac resistive | |
| Functions | Cyclic Management | ok |
| Serial Ports | RS485 | ok |
| System | Type | SLAVE |
| Maximum number of coil | 12 | |
| Type of control driver | RS485 |




Ms. Trinh