advanced-serial-system.png

ADVANCED SERIAL SYSTEM

Model: ECOSERIAL 3

ECOSERIAL 3
 
Main Features Features Values
Dimensions External Dimensions ( L x H x W mm ) 254x200x135
Weight (kg) 2,6
Protection Protection Level (standard) M IP55 / F IP56
Temperature Working Temperature (°C) -20... +60 vers.CE (OPT -40°C), -40... +65 vers. UL
Power Supply Power Supply Range (standard) 90-270Vac 50-60Hz
Power Consumption 10W
Display Display Type LCD
Resolution 128x64
Display Color (standard) yellow-green
Inputs Digital Inputs (nr) 4 opto-isolated inputs
Pressure Input ok
Pressure Range 0/+9999mmH2O, 0/+9999Pa, 0/+9.999kPa, 0/+99.99mBar
Analog Input optional
Outputs Relay Outputs (nr) 4
Relay Output Power 8A/270Vac
4-20mA Output optional
Functions Cyclic Management ok
Delta Pressure Management ok
Customizing Cycles ok
Remote Start/Stop ok
Autopause ok
Post-cleaning ok
Cleaning cycle ok (custom)
Coils can be activated simultaneously for each output (nr) 128
Broken Coil Control ok
Broken Valve Control ok
Pressure Tank Control ok
Broken Bag Control with D.Probe ok (advanced)
SMS Remote Control ok
Serial Ports RS485 ok
System Maximum Driver Managed 64 RPA / 16 RPC
Type MASTER
Type of driver connectable RPA/RPC
Type of control driver SERIAL
Management cell ok
Controls Buttons (nr) 4
Application Type Big Process dust collectors
 

Model: RPA-612

RPA-612
 
Main Features Features Values
Dimensions External Dimensions ( L x H x W mm ) 346x134x72
Protection Protection Level (standard) IP66, TYPE 4X
Temperature Working Temperature (°C) -40... +65
Power Supply Power Supply Range (standard) 90-270Vac
Power Consumption 90Vac 9VA, 270Vac 18.9VA
Inputs Digital Inputs (nr) 2
Analog Input ok
Outputs Relay Outputs (nr) 2
Relay Output Power 2A 30Vdc/250Vac resistive
Coils Control Voltage 24Vdc
Functions Cyclic Management ok
Broken Coil Control ok
Broken Valve Control ok
Pressure Tank Control ok
Serial Ports RS485 ok
System Type SLAVE
Maximum number of coil 12
Type of control driver RS485
 

Model: RPC

RPC
Main Features Features Values
Dimensions External Dimensions ( L x H x W mm ) 346x134x72
Protection Protection Level (standard) IP65
Temperature Working Temperature (°C) -10... +60 standard version, -20... +60 with one heater, -40... +60 with two heater
Power Supply Power Supply Range (standard) 90-270Vac
Power Consumption 90Vac 9VA, 270Vac 18.9VA
Inputs Digital Inputs (nr) 8 opto-isolated inputs
Analog Input ok
Outputs Relay Outputs (nr) 4
Relay Output Power 2A 30Vdc/250Vac resistive
Functions Cyclic Management ok
Serial Ports RS485 ok
System Type SLAVE
Maximum number of coil 12
Type of control driver RS485

COMPLETE SYSTEM ECOSERIAL3 + RPA-612

COMPLETE SYSTEM ECOSERIAL3 + RPA-612
 
 
DIMENSIONAL LAY-OUT 2