ENC-AR720EX-CU
Mount Type | Roof-mount |
---|---|
Cooling Capacity (W) | 600/700 |
Setting Temperature Range (°C) | 25 to 45 |
Use Area Temperature (°C) | 20 to 50 |
Use Area Humidity (%RH) | 10-85(No condensation) |
External Dimensions (mm) | H333×W550×D270 |
Volume (kg) | 22 |
Coating Color | Color Munsell 5Y7 / 1 light beige |
Voltage Rating (V) | Single-phase AC200 |
Consumption Current/Rating (A) | 1.9/1.4 |
Consumption Current/MAX (A) | 2.0/1.8 |
Starting Current (A) | 4.0/4.2 |
Consumption Voltage/Rating (W) | 285/265 |
Consumption Voltage/MAX (W) | 340/350 |
Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
Coolant / Filling (g) | HFC-134a 150g |
Noise (dB) | 60/65 |
External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
Display | LED / RUN LED display / temperature error in the panel |
Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
Environmental Response | RoHS |
ENC-AR1120EX-CU
Mount Type | Roof-mount |
---|---|
Cooling Capacity (W) | 950/1100 |
Setting Temperature Range (°C) | 25 to 45 |
Use Area Temperature (°C) | 20 to 50 |
Use Area Humidity (%RH) | 10-85(No condensation) |
External Dimensions (mm) | H318×W600×D353 |
Volume (kg) | 27 |
Coating Color | Color Munsell 5Y7 / 1 light beige |
Voltage Rating (V) | Single-phase AC200 |
Consumption Current/Rating (A) | 2.7/2.4 |
Consumption Current/MAX (A) | 3.2/3.3 |
Starting Current (A) | 7.5/7.1 |
Consumption Voltage/Rating (W) | 440/470 |
Consumption Voltage/MAX (W) | 570/630 |
Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
Coolant / Filling (g) | HFC-134a 240g |
Noise (dB) | 60/65 |
External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
Display | LED / RUN LED display / temperature error in the panel |
Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
Environmental Response | RoHS |
ENC-AR1652EX-CU
Mount Type | Roof-mount |
---|---|
Cooling Capacity (W) | 1500/1650 |
Setting Temperature Range (°C) | 25 to 45 |
Use Area Temperature (°C) | 20 to 55 |
Use Area Humidity (%RH) | 10-85(No condensation) |
External Dimensions (mm) | H448×W590×D350 |
Volume (kg) | 39 |
Coating Color | Color Munsell 5Y7 / 1 light beige |
Voltage Rating (V) | Single-phase AC200 |
Consumption Current/Rating (A) | 3.6/3.5 |
Consumption Current/MAX (A) | 4.4/4.5 |
Starting Current (A) | 16.5/15.5 |
Consumption Voltage/Rating (W) | 630/690 |
Consumption Voltage/MAX (W) | 800/860 |
Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
Coolant / Filling (g) | HFC-134a 440g |
Noise (dB) | 65/68 |
External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
Display | LED / RUN LED display / temperature error in the panel |
Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
Environmental Response | RoHS |
ENC-AR2200EX-CU
Mount Type | Roof-mount |
---|---|
Cooling Capacity (W) | 1900/2200 |
Setting Temperature Range (°C) | 25 to 45 |
Use Area Temperature (°C) | 20 to 55 |
Use Area Humidity (%RH) | 10-85(No condensation) |
External Dimensions (mm) | H447×W650×D400 |
Volume (kg) | 48 |
Coating Color | Color Munsell 5Y7 / 1 light beige |
Voltage Rating (V) | Three phase AC200 |
Consumption Current/Rating (A) | 3.3/3.2 |
Consumption Current/MAX (A) | 4.2/4.1 |
Starting Current (A) | 27/25 |
Consumption Voltage/Rating (W) | 850/1050 |
Consumption Voltage/MAX (W) | 1050/1250 |
Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
Coolant / Filling (g) | HFC-134a 575g |
Noise (dB) | 70/71 |
External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
Display | LED / RUN LED display / temperature error in the panel |
Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
Environmental Response | RoHS |
ENC-AR2900EX-CU
Mount Type | Roof-mount |
---|---|
Cooling Capacity (W) | 2600/2900 |
Setting Temperature Range (°C) | 25 to 45 |
Use Area Temperature (°C) | 20 to 55 |
Use Area Humidity (%RH) | 10-85(No condensation) |
External Dimensions (mm) | H447×W760×D400 |
Volume (kg) | 57 |
Coating Color | Color Munsell 5Y7 / 1 light beige |
Voltage Rating (V) | Three phase AC200 |
Consumption Current/Rating (A) | 4.8/4.7 |
Consumption Current/MAX (A) | 5.7/5.8 |
Starting Current (A) | 31/30 |
Consumption Voltage/Rating (W) | 1270/1450 |
Consumption Voltage/MAX (W) | 1700/1900 |
Noise Resistance | EN61000-3-2 EN61000-3-3 EN55014-1 EN55014-2 |
Vibration Resistance | 5Hz frequency 20mm total amplitude |
Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
Coolant / Filling (g) | HFC-134a 775g |
Noise (dB) | 72/73 |
External Output | Alarm output output / cooling operation (a contact: No-voltage resistive load 250V 2A) |
Display | LED / RUN LED display / temperature error in the panel |
Regulatory Compliance | CE marking, Standard UL, Electrical Appliance and Material Safety Law |
Environmental Response | RoHS |
Cooling capacity) Note: 35°C ambient temperature, the rated capacity of 35°C when the set temperature inside the panel.
(Method: JIS-C-9612 air enthalpy measurement conditions)
Ambient humidity / ambient temperature is not meant to satisfy all conditions in temperature and humidity.
RH 40% when the value of the maximum allowed ambient temperature, ambient humidity using an ambient temperature of use: The value MAX.
CE marking requirements in: noise resistance.
Please read instructions carefully before use, please use properly.