Apiste Precision Air PAU-A3500S-HC
Xuất sứ: Apiste
Nhà cung cấp: PITESCO Viet Nam
Hãng sản xuất: Apiste
Specifications
Cooling Method | Air-Cooled Type |
---|---|
Type | Temperature and humidity Controller |
Cooling Capacity (W) | 4500/5200 |
Heating Capacity (W) | 7800 |
Humidifying Capacity (kg/h) | 15.6 |
Temperature Control Precision (°C) | +-0.2 |
Setting Temperature Range (°C) | 20~30 |
Humidity Control Precision (%RH) | +-1.0 |
Setting Humidity Range (%RH) | 40~80 |
Use Area Temperature (°C) | 20 ~ 35 (change in temperature gradient: within 1°C/1h) |
Use Area Humidity (%RH) | 10 ~ 85 (change in temperature gradient: within 5%/1h) (No condensation) |
Processed Air Volume (m2/min)(50Hz) | 21/24 |
External Dimensions(mm) | H1481×W650×D1115 |
Volume (kg) | 260 |
Coating Color | Ivory (JPMA: Semi-gloss Y22-85B) |
Blower Duct Connection Diameter (mm) | φ200 with damper |
Rated Voltage (V) | Three-phase AC200 |
Consumption Current (A) | 7.5/8.5(MIN) 63.2/64.6(MAX |
Wattage (W) | 2000/2500(MIN) 21800/22300(MAX) |
Humidifier/Water Supply Volume (ℓ/h) | 18 |
Humidifier/Water Supply Pressure (MPa) | 0.03-0.5 |
Water Supply Temperature (°C) | 0-50 |
Humidifier/Water Supply Connection Diameter (mm) | 15A female socket (Rc: 1/2 inch) |
Drain Discharge Water Connection Diameter (mm) | 20A female socket (Rc: 3/4 inch) |
Coolant | R-407c 1470g |
Exhaust Air Volume (m3/min) | (Inverter control) 32.5/41.5 |
Safety Circuit/Main Circuit | Earth leakage circuit breaker (75A 30mA) |
Safety Circuit/Blower | Overcurrent relay (manual reset) (3.3A), Delay timer (3 minutes), Surge Absorber |
Safety Circuit/Compressor | Overcurrent relay, motor protectors, surge absorbers, low temperature thermostat driving prevention |
Safety Circuit/Heater | Thermostat to prevent overheating (65°C OFF 55°C ON), thermal fuse (99°C), surge absorber |
Safety Circuit/Humidifier | Float switch, thermostat to prevent overheating (120°C +- 10 ℃ OFF), fuse temperature (119°C), automatic timer drainage, drainage manual switch, surge absorber |
Output/Main Unit Malfunction Output | No-voltage contact a (AC250V / 3A / Resistive load) |
Output/Temperature Control Top-Bottom Limit Alarm | No-voltage contact a (AC250V / 3A / Resistive load) |
Output/Humidity Control Top-Bottom Limit Alarm | No-voltage contact a (AC250V / 3A / Resistive load) |
Dimensions
Sensor dimensions
Temperature & Humidity Control Range Chart
Measurement conditions(left table)
(1)AC200V 50Hz three-phase power supply:
(2)25°C ± 1°C / 40 +- 5% RH: ambient temperature and humidity
(3)9m 3 / min: the amount of wind blowing
(4)Sensor, the performance of the outlet duct insulation installed in the degree of bending once 4m90
Measurement conditions (table)
(1)AC200V 50Hz three-phase power supply:
(2)25°C +- 1°C / 50 +- 5% RH: ambient humidity
(3)18m 3 / min: the amount of wind blowing
(4)Sensor, the performance of the outlet duct insulation duct mounting degree of bending once 4m90
(1)AC200V 50Hz three-phase power supply:
(2)25°C ± 1°C / 40 +- 5% RH: ambient temperature and humidity
(3)9m 3 / min: the amount of wind blowing
(4)Sensor, the performance of the outlet duct insulation installed in the degree of bending once 4m90
Measurement conditions (table)
(1)AC200V 50Hz three-phase power supply:
(2)25°C +- 1°C / 50 +- 5% RH: ambient humidity
(3)18m 3 / min: the amount of wind blowing
(4)Sensor, the performance of the outlet duct insulation duct mounting degree of bending once 4m90