Apiste Panel Cooling Units Outdoor ENC-AR351HD, AR352HD, AR510HD, AR520HD, AR1010HD, AR1020HD, AR1610HD, AR1620HD, AR2900HD
Xuất sứ: Apiste
Nhà cung cấp: PITESCO Viet Nam
Hãng sản xuất: Apiste
ENC-AR351HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 300/380 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 0 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H530×W300×D115 |
| Volume (kg) | 15 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 3.7/3.5 |
| Consumption Current/MAX (A) | 3.9/3.8 |
| Starting Current (A) | 7.4/7.7 |
| Consumption Voltage/Rating (W) | 300/330 |
| Consumption Voltage/MAX (W) | 330/370 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | IP55 (Category 2) |
| Coolant / Filling (g) | HFC-134a 75g |
| Noise (dB) | 59/61.5 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 6 (M6 x L20) |
|---|---|
| Washer | (Flat washer) * 6 (spring washer) * 6 |
| Spacer | 6 |
| User Manual | 1 |
ENC-AR352HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 300/380 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | 0 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H530×W300×D115 |
| Volume (kg) | 15 |
| Coating Color | Color Munsell 5Y7 / 1 light beige |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 1.9/1.6 |
| Consumption Current/MAX (A) | 2.0/1.7 |
| Starting Current (A) | 4.0/4.2 |
| Consumption Voltage/Rating (W) | 300/285 |
| Consumption Voltage/MAX (W) | 330/320 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | IP55 (Category 2) |
| Coolant / Filling (g) | HFC-134a 75g |
| Noise (dB) | 59/61.5 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 6 (M6 x L20) |
|---|---|
| Washer | (Flat washer) * 6 (spring washer) * 6 |
| Spacer | 6 |
| User Manual | 1 |
ENC-AR510HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 450/550 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | -5 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H450×W350×D200 |
| Volume (kg) | 17 |
| Surface Finish | 180-HL No.4 NSSC finish |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 3.4/3.3 |
| Consumption Current/MAX (A) | 3.9/4.2 |
| Starting Current (A) | 7.4/7.7 |
| Consumption Voltage/Rating (W) | 300/335 |
| Consumption Voltage/MAX (W) | 365/410 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 105g |
| Noise (dB) | 59/63 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 5 (M6 x L20) |
|---|---|
| Washer | 2 |
| Spacer | 5 |
| Wind Direction Louver | 1 |
| Louvered Screw | 2 |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for AR510HD |
|---|---|
| External Fan | Air fan for AR510HD |
| Electrical Board | Substrate for AR510HD |
ENC-AR520HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 450/550 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | -5 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H450×W350×D200 |
| Volume (kg) | 17 |
| Surface Finish | 180-HL No.4 NSSC finish |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 1.9/1.5 |
| Consumption Current/MAX (A) | 2.1/1.9 |
| Starting Current (A) | 4.9/4.4 |
| Consumption Voltage/Rating (W) | 300/275 |
| Consumption Voltage/MAX (W) | 365/360 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 105g |
| Noise (dB) | 59/63 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 5 (M6 x L20) |
|---|---|
| Washer | 2 |
| Spacer | 5 |
| Wind Direction Louver | 1 |
| Louvered Screw | 2 |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for AR520HD |
|---|---|
| External Fan | Air fan forAR520HD |
| Electrical Board | Substrate for AR520HD |
ENC-AR1010HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 900/1000 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | -5 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H730×W300×D280 |
| Volume (kg) | 26 |
| Surface Finish | 180-HL No.4 NSSC finish |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 5.6/4.6 |
| Consumption Current/MAX (A) | 6.5/6.3 |
| Starting Current (A) | 15.6/14.7 |
| Consumption Voltage/Rating (W) | 440/450 |
| Consumption Voltage/MAX (W) | 595/615 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 225g |
| Noise (dB) | 64/66 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 6 (M6 x L20) |
|---|---|
| Washer | 2 |
| Spacer | 6 |
| Wind Direction Louver | 1 |
| Louvered Screw | 2 |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for AR1010HD |
|---|---|
| External Fan | Air fan for AR1010HD |
| Electrical Board | Substrate for AR1010HD |
ENC-AR1020HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 900/1000 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | -5 to 50 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H730×W300×D280 |
| Volume (kg) | 26 |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 2.6/2.3 |
| Consumption Current/MAX (A) | 3.1/3.0 |
| Starting Current (A) | 7.5/7.1 |
| Consumption Voltage/Rating (W) | 425/440 |
| Consumption Voltage/MAX (W) | 570/590 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 255g |
| Noise (dB) | 64/66 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 6 (M6 x L20) |
|---|---|
| Washer | 2 |
| Spacer | 6 |
| Wind Direction Louver | 1 |
| Louvered Screw | 2 |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for AR1020HD |
|---|---|
| External Fan | Air fan for AR1020HD |
| Electrical Board | Substrate for AR1020HD |
ENC-AR1610HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 1450/1600 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | -5 to 55 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H1000×W400×D260 |
| Volume (kg) | 42 |
| Surface Finish | 180-HL No.4 NSSC finish |
| Voltage Rating (V) | Single-phase AC100 |
| Consumption Current/Rating (A) | 7.6/7.0 |
| Consumption Current/MAX (A) | 8.5/8.8 |
| Starting Current (A) | 22.3/20.5 |
| Consumption Voltage/Rating (W) | 610/650 |
| Consumption Voltage/MAX (W) | 740/830 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | R-407c 300g |
| Noise (dB) | 65/68 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 6 (M8 x L25) |
|---|---|
| Washer | 2 |
| Spacer | 6 |
| Wind Direction Louver | 1 |
| Louvered Screw | 2 |
| Mounting nut | 2(M8) |
| Double-ended Screw | 2(M8) |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for AR1610HD |
|---|---|
| External Fan | Air fan for AR1610HD |
| Electrical Board | Substrate for AR1610HD |
ENC-AR1620HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 1450/1600 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | -5 to 55 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H1000×W400×D260 |
| Volume (kg) | 42 |
| Surface Finish | 180-HL No.4 NSSC finish |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 3.5/3.3 |
| Consumption Current/MAX (A) | 4.3/4.5 |
| Starting Current (A) | 13/12 |
| Consumption Voltage/Rating (W) | 610/670 |
| Consumption Voltage/MAX (W) | 780/840 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | R-407c 300g |
| Noise (dB) | 65/68 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 6 (M8 x L25) |
|---|---|
| Washer | 2 |
| Spacer | 6 |
| Wind Direction Louver | 1 |
| Louvered Screw | 2 |
| Mounting nut | 2(M8) |
| Double-ended Screw | 2(M8) |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for AR1620HD |
|---|---|
| External Fan | Air fan for AR1620HD |
| Electrical Board | Substrate for AR1620HD |
ENC-AR2900HD

| Mount Type | Side-mount |
|---|---|
| Cooling Capacity (W) | 2600/2900 |
| Setting Temperature Range (°C) | 25 to 45 |
| Use Area Temperature (°C) | -5 to 55 |
| Use Area Humidity (%RH) | 10-85(No condensation) |
| External Dimensions (mm) | H1380×W450×D295 |
| Volume (kg) | 60 |
| Surface Finish | 180-HL No.4 NSSC finish |
| Voltage Rating (V) | Single-phase AC200 |
| Consumption Current/Rating (A) | 7.8/7.3 |
| Consumption Current/MAX (A) | 9.3/9.4 |
| Starting Current (A) | 33/30 |
| Consumption Voltage/Rating (W) | 1300/1500 |
| Consumption Voltage/MAX (W) | 1650/1850 |
| Noise Resistance | Fast Transient / LEVEL4 by burst immunity test |
| Vibration Resistance | Equivalent to JIS Z 0200 Level1 |
| Dust & Water Protection Grade | Equivalent to IP54 (internal circulation route) |
| Coolant / Filling (g) | HFC-134a 500g |
| Noise (dB) | 68/70 |
| External Output | Alarm output (a non-voltage contact: Resistive load 250V 2A) |
| Display | LED RUN LED display / temperature error in the panel |
| Regulatory Compliance | Electrical Appliance and Material Safety Law |
| Environmental Response | RoHS |
Parts list supplied
| Mounting Bolt | 6 (M8 x L25) |
|---|---|
| Spacer | 6 |
| Mounting nut | 2(M8) |
| Double-ended Screw | 2(M8) |
| User Manual | 1 |
Maintenance Parts List
| Internal Circulation Fan | Circulation fan for AR2900HD |
|---|---|
| External Fan | Air fan forAR2900HD |
| Electrical Board | Substrate for AR2900HD |




Mr. Hà
live:ha_1652